Written by Javon Results and Discussion The results were obtained by the collaborators who performed the experiment. Figure 1: c/N vs c Table 1: c/N vs c c c/N 0.00342342 3.00598832 0.01837836 15.831308 0.04160156 22.6250274 0.06804798 30.7722158 0.09537528 38.5146221 0.12260248 4.45704831 Using the equation c/N = c/Nm + 1/kNm, Nm (number of moles of acetic acid required to forma monolayer onto the charcoal) can be approximated as the inverse of the slope of the best fit line. The […]
Written by Johanna ABSTRACT: This experiment effectively determined the differences between Iron (II) and Ruthenium (II) Tris-2,2’-bipyridine complexes through the comparison of absorption and emission spectroscopy and cyclic voltammetry. In both the UV/Vis absorption and emission spectra, the Ru (II) complex shows far greater molar absorptivity values and fluorescence. The iron complex does not fluoresce. The MLCT peaks in the UV/Vis spectra correspond to the energy of the t2g à t2g* or HOMO à LUMO transitions, 2.64 x 105 J/mol […]
Written by Jimmy Table of 1H NMR Spectral Data of Ketal ester Table of 13C NMR Spectral Data of Ketal ester Table of IR Spectral Data of Ketal ester Provide your experimental index of refraction and correction factor: 1.4229 @ 22ºC 1.4229+0.00045*2=1.4238 Literature=1.4377 Reproduce your Theoretical and Percent Yield Calculations. Ethyl Acetoacetate: 10.0 mL (1.029g/mL) (1/130.14g/mol) = 0.0791 mol Glycol: 4.5 mL (1.113g/mL) (1/62.07g/mol) = 0.0807 mol 1:1 ratio of prods to reacts and reacts […]
Written by Hannah Purpose To measure the grams of yellow 5 dye in a sample (i.e. bottle of Minute Maid Lemonade), and to identify the cations present in sparklers using their emission spectra (Spectroscopy). Procedure Six standard solutions were made from the Yellow 5 stock solution. The first standard solution was made by adding 5.00 mL 6.550×10-5 M yellow 5 solution and 2.00 mL of distilled water to a test tube using a graduated pipet and by subsequently mixing […]
Written by Morgan I. Introduction: This experiment is concerned with determination of the concentration of a standard solution of HCl. Coulometric titrations are performed using MicroLab FS 522 with MicroLab Model 290 sensor adaptor module to gather data regarding electric current variability. The theories underlying this variety of titration include redox reactions, current and total charge, and the techniques of coulometric measurement of electrolysis can be found in the following materials1: D.C. Harris, Quantitative Chemical Analysis, 8th ed., W.H. Freeman, […]
Written by Robert Purpose: To use solvent extraction techniques to separate a mixture consisting of a carboxylic acid, a phenol, and a neutral compound and to determine the melting points of said chemicals. Description: For this experiment, we used the following materials: (4) 100 mL beakers, 400 mL beaker with ice, Buchner funnel, 125 mL Erlenmeyer Flask, 250 mL filter flask, filter paper, glass stirring rod, 25 mL graduated cylinder, hot plate, melting point capillary tubes, disposable pipets, pH test […]